3/31/2022

Storage Drive 5 Drive Slot Sensor For Storage Drive Fault Was Asserted

Product Description

The Oracle Exadata Storage Server X8-2 is an enterprise-class, two rack unit (2U) server that is available in three configurations: Extreme Flash (EF), High Capacity (HC), and Extended (XT). Each configuration uses the same server but is provisioned differently, as described in the following table.

  1. The Oracle Exadata Storage Server X8-2 is an enterprise-class, two rack unit (2U) server that is available in three configurations: Extreme Flash (EF), High Capacity.
  2. BP Drive 0: Drive Slot sensor for BP, drive fault was asserted. Any further suggestions as to what the problem might be? The fault also occurs when I boot the Live System from the link above. The system does work and I have no issues at all, but its annoying to have a fault indication for no apparent reason.
  3. Drive backplane 0 Pri Drv0 Stat 0: Drive fault - Assert ALERT Drive backplane 0 Pri Drv0 Stat 0: Parity check in progress - Assert WARNING The only other warning is the Battery on Controller 0 - Learn cycle complete / Battery Status: Charging for the RAID battery card.
Storage drive 5 drive slot sensor for storage drive fault was asserted designed

Storage Drive 5 Drive Slot Sensor For Storage Drive Fault Was Asserted Added

Sensor 1 of the Internal storage device on SCSI port 1 of the Compaq Smart Array Controller (in slot 2) is reporting the internal temperature has exceeded the preset limit. The controller may attempt to shut down power to the storage device and/or spin down the installed hard disk drives.

Storage Drive 5 Drive Slot Sensor For Storage Drive Fault Was Asserted One

Processor
  • Two Intel Xeon Gold 5218, 16-core, 2.3 GHz, 125 W processors (EF and HC only)

  • One Intel Xeon 12-core, 2.3 GHz, 125 W processor in socket P0 (XT only)

  • Twelve 16 GB (192 GB) 2666 MT/sec DDR4 DIMMs, or a configuration that supports six 128 GB DCPMM DIMMs per processor for a maximum of 12 DCPMM DIMMs alongside the 16 GB DDR4 DIMMs in the same memory channel (EF and HC only)

  • Six 16 GB (96 GB) 2666 MT/sec DDR4 DIMMs (XT only)

Eleven PCIe Gen3 slots
  • Eight Oracle Flash Accelerator F640 PCIe cards: 6.4 TB, NVMe PCIe 3.0 (EF only)

  • Four Oracle Flash Accelerator F640 PCIe cards: 6.4 TB, NVMe PCIe 3.0 (HC only)

  • One Oracle Dual Port QDR InfiniBand Adapter M3 or Oracle Dual Port 100 Gb Ethernet Adapter

  • One Oracle Storage 12Gb SAS PCIe RAID HBA, Internal Card (HC and XT only)

Twelve storage drive slots
  • Twelve storage drive slot fillers (EF only)

  • Twelve 3.5-inch 14 TB HDDs (HC and XT only)

Two internal 240 GB SATA M.2 flash SSDs (used for system boot and rescue functions)
Two hot-pluggable, redundant 1200 W power supplies
On-board Oracle Integrated Lights Out Manager (Oracle ILOM) service processor (SP) based on the ASPEED Pilot 4 chip